Direct Fired Air Heater   --     Job Reference  W42618

Home        Products         Rentals         Services        Tech Section       Users

 

NAO Horizontal Air Heater   ---   Flow   13450 SCFM   715 degr F

          36" OD by 12' Long     Air Pressure -- 6" WC     Fuel -- Natural Gas (2.5 PSIG)

           Complete with:  Digital temperature control, Nema 4 Weatherproof control panel, NAO
                                       JET MIX™ burner with spark ignited gas fired pilot, gas piping trains for
                                       main burner and pilot with double block & bleed solenoid valves (FIA Code),
                                       manual shutoff valves, UV flame scanner & safeguard control, low fire start
                                       with air & temperature modulation/control by means of pneumatic damper/valve
                                       for the combustion air blower and burner, air blower, flow transmitters for fuel
                                       gas and combustion air, thermocouple, fuel gas pressure gage, pilot gas
                                       pressure gage & high temperature glass sightport

 

 

Detail of weatherproof control panel & piping trains for main burner fuel and pilot gas -- FIA Code (double block & bleed valves) for main gas supply

 

Email or fax NAO for more information, please reference JOB W42618.